The bandwidth of a series R-L-C circuit at resonance is given by
Official theoretical question paper for Basic Electrical Engineering (ES-EE101) conducted by Maulana Abul Kalam Azad University of Technology. All questions from Groups A, B, and C are reproduced below with marks weightings.
The bandwidth of a series R-L-C circuit at resonance is given by
Transformer core is laminated to reduce
Power factor for AC resistive circuit is
For R-L-C series resonance circuit, line current at resonance frequency is
Two impedances (10 + j10) Ω and (10 - j10) Ω are connected in parallel. Their equivalent impedance is
The direction of rotation of a DC motor is given by
One commercial unit of electricity equals
If a DC-DC buck converter of input voltage V has chopping frequency of 'f' and T_ON as the on time of the switch, then the output voltage is
The insulation resistance of earth of an installation should be nearly
Form factor is the ratio of
A device that converts a DC source into AC is called
Derive an expression for growth of current and decay of current through an inductor at transient state.
Derive an expression for resonant frequency of an R-L-C series resonant circuit. Why is this circuit called acceptor circuit?
State and explain Norton's theorem with suitable example.
Explain the principle of operation of MCB.
Derive the relation between phase and line voltages for star connected load across 3 phase balanced system. Draw necessary circuit and phasor diagram.
A 3 phase 400 V circuit has a power factor of 0·8 (lagging). Two watt-meters are connected to measure the total input power which is 20 kW. Determine the reading of each wattmeter.
a) Derive the relation between phase and line voltages for star connected load across 3 phase balanced system. Draw necessary circuit and phasor diagram. b) A 3 phase 400 V circuit has a power factor of 0·8 (lagging). Two watt-meters are connected to measure the total input power which is 20 kW. Determine the reading of each wattmeter. c) Draw speed vs torque characteristics of 3-phase induction motor. Can an induction motor run in synchronous speed?
A balanced 3-phase supply in a 3-phase induction motor produces uniform rotating magnetic field. Explain it analytically.
A 3-phase 6-pole 50 Hz induction motor has a slip of 1% at no load and 3% at full load. Determine (i) synchronous speed, (ii) no load speed, (iii) full load speed, (iv) frequency of rotor current at standstill, (v) frequency of rotor current at full load.
a) Derive the relation between phase and line voltages for star connected load across 3 phase balanced system. Draw necessary circuit and phasor diagram. b) A 3 phase 400 V circuit has a power factor of 0·8 (lagging). Two watt-meters are connected to measure the total input power which is 20 kW. Determine the reading of each wattmeter. c) Draw speed vs torque characteristics of 3-phase induction motor. Can an induction motor run in synchronous speed?
How many types of power are there? Explain with their units. Establish their relationship using power triangle.
Explain why a dc series motor should not be started without a load?
a) Derive the relation between phase and line voltages for star connected load across 3 phase balanced system. Draw necessary circuit and phasor diagram. b) A 3 phase 400 V circuit has a power factor of 0·8 (lagging). Two watt-meters are connected to measure the total input power which is 20 kW. Determine the reading of each wattmeter. c) Draw speed vs torque characteristics of 3-phase induction motor. Can an induction motor run in synchronous speed?
State and explain Thevenin's theorem.
Find the current in the 50 Ω resistor as shown in the figure below using Superposition theorem.
a) Derive the relation between phase and line voltages for star connected load across 3 phase balanced system. Draw necessary circuit and phasor diagram. b) A 3 phase 400 V circuit has a power factor of 0·8 (lagging). Two watt-meters are connected to measure the total input power which is 20 kW. Determine the reading of each wattmeter. c) Draw speed vs torque characteristics of 3-phase induction motor. Can an induction motor run in synchronous speed?
Draw an equivalent circuit and phasor diagram at rated load (lagging power factor) of a single phase transformer.
A 125 kVA transformer having primary voltage of 2000 V at 50 Hz has 182 primary and 40 secondary turns. Neglecting losses, calculate i) full load primary and secondary currents, ii) the no-load secondary induced emf, iii) the max. flux in the core.
What will happen if a DC supply is given to a transformer?